AMCO-AEPA-1
Turbidity Calibration Solution at 0 FTU, 30 mL bottle
The
HI-93703 ISO compliant turbidity meter is designed to be routinely
standardized with a known light scattering standard. As with all
analytical standards or reference materials, a turbidity standard should
be able to perform the following: provide traceability, demonstrate the
accuracy of results, calibrate the equipment and methodology, monitor user
performance, validate tests, and facilitate comparability. Standardization
ensures that when the correct procedures have been followed, the same
analysis of the same materials will produce results that agree with each
other whenever they are performed.
Hanna
turbidity standards are prepared from AMCO AEPA-1 materials that are known
for being highly stable and reliable for standardization. AMCO AEPA-1
turbidity standard is a stabilized suspension of cross linked styrene
divinylbenzene copolymer microbeads in ultrapure water. These beads are
chemically inert and keep their chemical balance in a water medium
regardless of concentration. Particle size, uniform shape, and refractive
index make these spheres ideal to characterize light absorption and
scatter for 90° behavior
in the UV-VIS range. In addition, the bead’s spherical shape and size
helps prevent the accumulation or precipitation of the standard. For these
reasons, the AMCO AEPA-1 standard is very stable.
This
standard is prepared and bottled in a clean room facility. It is tested
and validated for accuracy and stability, and certified as free from any
toxic chemicals or compounds. The prepared standard is compared to
formazin turbidity standard solutions. The values obtained and the date of
analysis are reported on the supplied certifcate of analysis.
HI-93703-0
is a high quality turbidity calibration standard that allows users to
validate and calibrate the HI-93703 turbidity meter that has a 0 to 1000
FTU range. HI-93703-0 includes one standard solution with an expected
reading of 0 FTU. The calibration standard is produced in a
state-of-the-art manufacturing facility using NIST traceable reference
materials in a temperature controlled environment.
Supplied
with Certificate of Analysis
- Lot
number
- Expiration
date
- Standard
value
- Reference
meter NIST traceable
Provided
storage containers
- Light
tight
- Protects
from accidental breakage
The
HI-93703-0 turbidity calibration standard is made specifically for the
HI-93703 turbidity meter. The calibration process is quick and easy.
Brand : Hanna Instruments
