Cheese
pH Portable Meter (HACCP)
The
HI-99165 is a durable, waterproof, and portable Foodcare pH and
temperature meter designed specifically for cheese analysis. Automatic
calibration is performed at one or two points with two sets of buffers.
All calibration and measurement readings are automatically compensated for
temperature variations.
The
HI-99165 uses the FC2423 stainless steel body, amplified pH electrode
that offers numerous features that improve pH testing for cheese
producers. The split-level LCD displays both pH and temperature
readings, along with indicators for reading stability, battery
percentage, and calibration instructions.
- Automatic
Temperature Compensation
- Automatic
Two-Point Calibration
- Waterproof
pH
is an essential measurement throughout the entire cheesemaking process.
From the initial measurements of incoming milk to the final measurements
of ripened cheese, pH is the most important parameter for cheese quality
and safety control.
Acidification
of milk begins with the addition of bacterial culture and rennet. The
bacteria consume lactose and create lactic acid as a byproduct of
fermentation. The lactic acid produced will cause the pH of the milk to
go down. Once the milk reaches a particular pH, the rennet is added. The
enzymes in rennet help to speed up curdling and create a firmer
substance. For cheesemakers that dilute their rennet, the pH of the
dilution water is also critical; water that is near pH 7 or higher can
deactivate the rennet, causing problems with coagulation.
Once
the curds are cut, stirred, and cooked, the liquid whey must be drained.
The pH of whey at draining directly affects the composition and texture
of the final cheese product. Whey that has a relatively high pH
contributes to higher levels of calcium and phosphate and results in a
stronger curd. Typical pH levels at draining can vary depending on the
type of cheese; for example, Swiss cheese is drained between pH 6.3 and
6.5 while Cheddar cheese is drained between pH 6.0 and 6.2.
During
brining, the cheese soaks up salt from the brine solution and loses
excess moisture. The pH of the brine solution should be close to the pH
of the cheese, ensuring equilibrium of ions like calcium and hydrogen.
If there is an imbalance during brining, the final product can have rind
defects, discoloration, a weakened texture, and a shorter shelf life.
Cheeses
must fall within a narrow pH range to provide an optimal environment for
microbial and enzymatic processes that occur during ripening. Bacterial
cultures used in ripening are responsible for familiar characteristics
such as the holes in Swiss cheese, the white mold on Brie rinds, and the
aroma of Limburger cheese. A deviation from the ideal pH is not only
detrimental to the ecology of the bacteria, but also to the cheese
structure. Higher pH levels can result in cheeses that are more elastic
while lower pH levels can cause brittleness.
The
HI99165 uses the stainless steel FC2423 amplified pH electrode. This
specialized electrode offers numerous features that improve pH testing
for cheese producers. The robust stainless steel sheath paired with the
conical sensing tip allows for penetration in cheese at various points
throughout the production process. An integrated temperature sensor also
ensures that all pH measurements are compensated for temperature without
the need for a separate temperature probe.
Stainless
Steel Body
The
AISI 316 stainless steel body offers durability in the production
facility and can withstand chloride concentrations that cause
corrosion in other types of alloys..
Conic
Glass Tip
The
conical shaped tip design allows for penetration into solids,
semi-solids, and emulsions for the direct measurement of pH in samples
such as cheese.
Built-In
Temperature Sensor
Errors
in calibration and measurement are eliminated with the Automatic
Temperature Compensation provided by the integrated temperature
sensor.
Features
- Waterproof
- Automatic
Calibration
- Automatic
Temperature Compensation
- Multi-Level
LCD Display
- Sensor
Check
- Probe
Condition Indicator
- Battery
Error Prevention System
- Battery
Life Indicator
Specifications
pH
Range |
-2.00
to 16.00 pH; -2.0 to 16.0 pH |
pH
Resolution |
0.01
pH; 0.1 pH |
pH
Accuracy |
±0.02
pH; ±0.1 pH |
pH
Calibration |
automatic,
at one or two points with two sets of buffers (standard 4.01,
7.01,10.01 or NIST 4.01, 6.86, 9.18) |
pH
Temperature Compensation |
Automatic
‐5.0 to 105.0 °C/23.0 to 221.0 °F |
pH
CAL Check (electrode diagnostics) |
probe
condition indicator |
pH
Sensor Check |
yes |
mV
Range |
±825
mV (pH‐mV) |
mV
Resolution |
1
mV (pH‐mV) |
mV
Accuracy |
±1
mV (pH‐mV) |
Temperature
Range |
-5.0
to 105.0°C / 23.0 to 221.0°F |
Temperature
Resolution |
0.1°C
/ 0.1°F |
Temperature
Accuracy |
±0.5°C
(up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F
(outside) |
pH
Electrode |
FC2423
pre-amplified pH probe with internal temperature sensor, quick
connect DIN connector and 1 m (3.3’) cable (included) |
Automatic
Shut-Off |
user
selectable |
Battery
Type/Life |
1.5V
(3) AAA / approximately 1400 hours of continuous use |
IP
Protection |
IP67 |
Environment |
0
to 50°C (32 to 122°F); RH max 100% |
Dimensions |
154
x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
Weight |
196
g (6.91 oz.) |
Product Manual
Brand : Hanna Instruments