OCTYPE html>
pH/EC/TDS
Multiparameter Probe - HI-1285-5
pH/EC/TDS electrode
for greenhouses, hydroponics, environmental monitoring, water treatment,
boilers with multi-pin connector recommended for HI-9811-5, HI-9812-5
and HI-9813-5 series
The
HI-1285-5 is a 3-in-1 pre-amplified multiparameter probe that measures pH,
EC/TDS, and temperature within a single polypropylene body. The pH portion
of this probe is constructed with a cloth junction, maintenance-free
polymer gel electrolyte, and a low-temperature glass sensing bulb. The
EC/TDS portion of this probe utilizes two stainless steel pins for an
amperometric determination of conductivity and total dissolved solids. A
built-in temperature sensor ensures that both pH and EC/TDS readings are
compensated for temperature variations in both standards and samples.
The
design consideration for the HI-1285-5 is ideal for measuring the pH,
EC/TDS, and temperature in greenhouses, hydroponics, environmental
monitoring, water treatment, and boilers and cooling towers. The HI-1285-5
is designed for use with Hanna’s HI-9813-5, HI-9812-5, and HI-9811-5
portable multiparameter meters.
- Pre-amplified
pH electrode
- Amperometric
EC/TDS sensor
- Built-in
temperature sensor
Hanna
Instruments offers a wide variety of electrodes that are designed for many
different applications. The sensing material, body material, and
connection type used are just some of the design considerations.
Pre-Amplified
pH Electrode
The
pH electrode circuit has a built-in amplifier that serves to reduce the
effects of electrical noise on the high impedance pH measurement.
Electrical noise can come from motors and pumps that are common in
greenhouses. The single reference junction design of the pH electrode
has a cloth junction that allows ion movement between the inner gel
electrolyte and the sample being measured. The advantage of the cloth
junction is that it can be extracted from the probe, exposing a fresh
surface when readings become drifty or erratic. These features make this
probe ideal for use in fertilizer solutions.
Amperometric
EC/TDS Sensor
EC/TDS
readings are performed by a two-pin amperometric sensor. An alternating
voltage is applied to the sensor and the amount of current that passes
between the two stainless steel pins determines the amount of dissolved
ionic solids present.
Built-In
Temperature Sensor
pH
and EC/TDS readings must be temperature compensated in order to obtain
accurate results. The built-in temperature sensor of the HI1285-5
provides a speedy temperature reading which is then used to adjust the
pH and EC/TDS results accordingly.
Polypropylene
Body
The
polypropylene body of the HI1285-5 houses all three sensors within a
sturdy, single body design. This body material is suitable for a wide
range of applications and excels in measurements with portable meters
due to its durability. The fins around the spherical glass pH bulb
minimizes breakage due to accidental bumping or dropping of the
electrode. The polypropylene plastic is a high-quality plastic that is
chemically resistant to many aggressive chemicals.
DIN
Connector
The
HI1285-5 uses a DIN connector. This type of connector is generally
proprietary to the meters they are supplied with and may not be
interchangeable. The HI1285-5 is designed for use with Hanna’s HI9813-5,
HI9812-5, and HI9811-5 portable multiparameter meters.
Reference
Cell Type |
single,
Ag/AgCl |
Junction
Type/Flow Rate |
cloth |
Type
of Electrolyte |
gel |
Body
Material |
polypropylene |
Glass
Type |
LT |
Tip
/ Shape |
spheric
(8 mm) |
Matching
Pin |
no |
Max.
Pressure |
0.1
bar |
Optimum
pH Range |
0
to 13 |
Temperature
Operating Range |
0
to 50°C (32 to 122°F) |
Body
Length/Overall Length |
95
mm / 185 mm |
Temperature
Sensor |
yes |
Outer
Diameter |
16
mm |
Cable |
7-pole;
1 m (3.3 in.) |
Connector
Type |
DIN |
Amplifier |
yes |
Recommended
Use |
Greenhouses,
hydroponics, environmental monitoring, water treatment, boilers,
cooling towers |
Brand : Hanna Instruments