These lead shields are useful for safer storage. The school grade radioactive
sources are mounted in a 25mm diam. x 5mm thick plastic disc with the symbol
printed. Although radioactivity level is very low, the sources should not be carried
around for long periods or placed in pockets of clothing against one’s body.
Cat No: Material: Particle: Strength:
PA2667-005 Polonium 210 Alpha particle 0.1 uCi or 3.7 kBq (+/- 1)
PA2667-010 Strontium 90 Beta particle 0.1 uCi or 3.7 Kbq (+/- 1)
PA2667-020 Cobalt 60 Gamma particle 1.0 uCi or 37 kBq (+/- 10)
Useful conversion information:
1 Bq (Becquerel) = 1 disintegration per second = 27 x 10-12 Curie (Ci)
1 kBq = 27 x 10-9 nCi (nano Curie)
1 kBq = 27 x 10-6 uCi (micro Curie)
1 Ci = 37 x 109 Bq = 37 GBq (giga Becquerel)
CAUTION TO BE FOLLOWED:
These school grade radioactive sources have a very low level of activity and do not
require licensing, however they should be handled with care. The following rules
should be followed:
• Unnecessary handling of sources should be avoided. Do not place into
pockets of clothing or carry bags etc..
• As general practice, radioactive sources should always be handled with tongs
or forceps to keep them at least 30cm away from user.
• Handle the alpha source with special care to avoid damage to the fragile
metallic coating over the material.
• For Alpha sources, a thin aluminium sheet provides sufficient absorption.
• For Beta sources, about 4 to 6mm thick lead is required for full absorption.
• For Gamma sources, thick lead is required to absorb most of the radiation
Product Information
Brand : IEC